↑日記で日々積み重ねた情報をトップの「わんこのページ」にまとめています。

おのたく日記 [RDF] YouTubeも始めました→


2018-11-12(Mon) [長年日記]

[ZFS][HDD] HDDやはり壊れた

ZFSからエラーのメールを頂いていたのを、昨日の日記で書いたけど、今日はSMARTからもメールが来た。

# smartctl -l error /dev/sdb

smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.18.0-2-amd64] (local build)

Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===

SMART Error Log Version: 1

ATA Error Count: 2

CR = Command Register [HEX]

FR = Features Register [HEX]

SC = Sector Count Register [HEX]

SN = Sector Number Register [HEX]

CL = Cylinder Low Register [HEX]

CH = Cylinder High Register [HEX]

DH = Device/Head Register [HEX]

DC = Device Command Register [HEX]

ER = Error register [HEX]

ST = Status register [HEX]

Powered_Up_Time is measured from power on, and printed as

DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,

SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 2 occurred at disk power-on lifetime: 42730 hours (1780 days + 10 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:

ER ST SC SN CL CH DH

-- -- -- -- -- -- --

40 51 d8 a0 a2 d4 0f Error: UNC 216 sectors at LBA = 0x0fd4a2a0 = 265593504

Commands leading to the command that caused the error were:

CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name

-- -- -- -- -- -- -- -- ---------------- --------------------

25 00 00 78 a2 d4 e0 08 3d+14:16:29.677 READ DMA EXT

35 00 58 50 e7 79 e0 08 3d+14:16:29.677 WRITE DMA EXT

b0 d0 01 00 4f c2 00 08 3d+14:16:29.489 SMART READ DATA

35 00 90 e0 75 48 e0 08 3d+14:16:29.489 WRITE DMA EXT

ef 10 02 00 00 00 a0 08 3d+14:16:29.489 SET FEATURES [Enable SATA feature]

Error 1 occurred at disk power-on lifetime: 42722 hours (1780 days + 2 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:

ER ST SC SN CL CH DH

-- -- -- -- -- -- --

84 51 ba 46 83 61 08 Error: ICRC, ABRT at LBA = 0x08618346 = 140608326

Commands leading to the command that caused the error were:

CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name

-- -- -- -- -- -- -- -- ---------------- --------------------

61 00 80 00 83 61 40 08 3d+06:13:43.240 WRITE FPDMA QUEUED

61 00 50 00 82 61 40 08 3d+06:13:43.240 WRITE FPDMA QUEUED

61 00 78 00 81 61 40 08 3d+06:13:43.239 WRITE FPDMA QUEUED

61 a0 d8 10 d8 35 40 08 3d+06:13:43.239 WRITE FPDMA QUEUED

61 80 48 50 73 10 40 08 3d+06:13:43.239 WRITE FPDMA QUEUED

というとこなので、2013年12月の日記から、5年近く使ったHDDも交換だね。3TB→8TBにする。

本日のPingbacks(全0件)

Google Web検索 on-o.com内を検索